NETWORK OR APPLICATION
Determine whether the problem lies in the network path, outside the network or where the two meet. We treat flow data and active measurements as first-class evidence in the diagnosis.
AI NOC brings more than 100 AI playbooks, hundreds of failure scenarios and one answer: where the problem is. From a faulty ACL rule to a carrier link outage. And you can run it all locally, without sending data outside your organization.
Determine whether the problem lies in the network path, outside the network or where the two meet. We treat flow data and active measurements as first-class evidence in the diagnosis.
Each playbook investigates a group of related problems: it knows what to read, which hypotheses to test and what evidence to require. Together they cover several hundred fault types.
Every conclusion comes with sources, counterarguments and explicit confidence limits. When data is missing, the report says so plainly.
The AI model can run in your infrastructure, so data doesn't leave your environment. AI NOC has read-only access to your systems, and the operator always makes the decision.
Each playbook investigates a group of related problems, from the physical layer to the services the network depends on. Below are selected problems from the catalog.
The scope of diagnosis in a PoC depends on the data sources we connect: flow data from Sycope, active measurements, SNMP and syslog, DNS, DHCP or CMDB.
In the recommended on-prem deployment, the entire analysis takes place in your infrastructure: from reading the data, through the AI model, to the report.
The model runs on a server in your infrastructure. Data about your network, incidents and evidence doesn't go to Sycope or to external AI providers.
AI NOC uses a pre-trained model. Data is used only to analyze the incident, not for training.
Queries to data sources are run by the AI NOC control layer: read-only, allowed tools only, with limits.
AI NOC has no write tools. Even if text posing as a command appears in the logs, the model can't use it to change the configuration.
Every diagnosis records the queries, tools used, evidence, and questions and answers. Your security team can see what AI NOC read and why.
We agree on retention and post-PoC data deletion before the start. You can cut off AI NOC's access to data sources at any time.
Sycope AI NOCSee how Sycope AI NOC automates incident diagnostics, verifies hypotheses and gives engineers conclusions backed by concrete data.
In the recommended on-prem deployment, nowhere outside your infrastructure. The data sources, the AI NOC application, the AI model and the collected evidence all run on your side. Sycope has no remote access to them. The exception is anything you choose to show during a support session, e.g. a shared screen or a log excerpt. That is always your decision.
In the online deployment, the analysis context is sent to an agreed model provider. We enable it only at your request, and before the start we describe the scope of transferred data, the region, data copies, logs and support access.
AI NOC records the course of each analysis on your side: queries, context, responses and evidence. This makes every diagnosis traceable. We agree on retention and post-PoC data deletion rules at the outset. On request, we will sign an NDA or a data processing agreement.
The model doesn't learn from your data. AI NOC uses a pre-trained model, and data is used only to analyze the specific incident. In the on-prem deployment, the model runs locally, with no connection to the model provider.
The model doesn't connect to your systems on its own. Queries are run by the AI NOC control layer, with read-only access, a list of allowed tools and limits. That's why even a manipulation attempt, such as text in the logs posing as a command, can't lead to a change in the network: AI NOC has no write tools. Every step of the analysis goes into the audit trail.
We don't claim the model never makes mistakes. That's why every diagnosis shows evidence for and against, and the operator makes the decision.
No. AI NOC works in advisory mode. It reads data from agreed sources through accounts with no permission to change configuration, and writes only its own tasks, reports and evidence. The decision to act is always made by the operator.
Reading alone also puts load on systems. That's why in a PoC we set limits on query time, number and concurrency, and run active measurements only against agreed targets and at an agreed frequency.
In the on-prem deployment, you need a VM for the AI NOC application and a GPU server for the model. In the online deployment, a provider endpoint is enough instead of a server. On top of that, read-only access to Sycope and agreed sources, e.g. active measurements, SNMP, syslog, DNS, DHCP or CMDB. We recommend a separate VM for AI NOC and separate resources for the model.
We don't have a universal hardware requirements sheet yet, so we match the hardware to your scenarios during the qualification call. The timeline depends mainly on the number of sources and your internal change procedures. The first goal is a working scenario: a connected source, correctly identified assets and time, an approved playbook and a report assessed by an operator. The measurement history needed depends on the playbook. This is not an AI “learning” period.
If your policy requires operation without Internet access (air-gapped), we will test that setup in a PoC on your configuration.
AI NOC runs diagnostics using more than 100 playbooks. Each one covers a group of related problems, several hundred fault types in total. Examples from the catalog:
For every incident, you get a report with the probable cause, evidence for and against, confidence limits and next steps. When evidence is missing or out of date, the result reads “insufficient evidence” instead of a guess. The console works in Polish and includes a chat about the selected incident, with links to sources.
The scope of diagnosis in a PoC depends on the data sources we connect.
It doesn't perform fixes or make changes to the network. A diagnosis is started by an operator or an alert: AI NOC doesn't watch the network continuously, doesn't predict failures and doesn't produce recurring reports. The chat covers the selected incident: it doesn't answer arbitrary questions about all of your telemetry and doesn't launch new analyses. AI NOC doesn't yet automatically use the history of similar incidents or your runbooks. Integrations beyond Sycope require qualification for the specific scenario, and without data from a given source a playbook can't reach a full diagnosis. It doesn't replace monitoring or APM, and it isn't a SOC module.
Diagnoses may overinterpret the evidence, which is why an operator verifies each one. The confidence stated in the report is not a measured probability of correctness. Analysis takes minutes, not seconds.
Better to hear this now than in week three of the PoC.